• Shop
  • Products
    • Airflow Management
    • Batteries & Battery Monitoring
    • Cooling
    • KVM
    • Monitoring
    • Power
    • Racks & Enclosures
  • Services
    • Commissioning
    • Design Engineering
    • Installation and Startup
    • NOC/24-7-365
    • Preventative Maintenance
    • New Network Creation
  • Industries
    • Data Centers
    • Utilities
    • Transportation
    • Medical
    • Telecom
    • Education
    • Retail
    • Manufacturing
    • Government / Military
    • Business Offices
  • About
    • Our Team
    • Partners
    • Testimonials
    • Line Card
    • Government Capability Statement
  • Blog
  • Contact
  • Privacy Policy
  • Terms and Conditions (“Terms”)
  • 877.592.4259
  • Menu
  • Skip to right header navigation
  • Skip to main content
  • Skip to primary sidebar
  • Skip to footer

Before Header

  • Contact Us
  • 877.592.4259
  • My account
  • Cart
  • Checkout

PTI Solutions: Predictive Technology, Inc.

PTI Solutions

  • Shop
  • Products
    • Power
    • Airflow Management
    • Batteries & Battery Monitoring
    • Racks & Enclosures
    • KVM
    • Cooling
    • Monitoring
  • Services
    • Preventative Maintenance
    • NOC/24-7-365
    • Design Engineering
    • Installation and Startup
    • Commissioning
    • New Network Creation
  • Industries
    • Data Centers
    • Utilities
    • Transportation
    • Medical
    • Telecom
    • Education
    • Retail
    • Manufacturing
    • Government / Military
    • Business Offices
  • About
    • Our Team
    • Partners
    • Testimonials
    • Line Card
    • Government Capability Statement
  • Blog
  • Search
You are here: Home / Battery Monitoring / Four Factors that Affect Data Center Battery Life

Four Factors that Affect Data Center Battery Life

//  by Angela Wilson

Batteries are the life support for your UPS and generator power systems. They protect you during power outages.

Power losses are difficult to predict. They can be caused by a number of factors including natural disasters, storms, poor power grid technology, and people.

So you say to me, “I have redundancy throughout my data center. I do PM’s on my batteries, so I am fine.” That’s great! However, neither of those will protect the weakest link in your facility – the batteries.

Batteries need to be well cared for so they’re ready to do their job when there is a power crisis in your facility.

In 2020 this is more important now than ever. As we navigate through the COVID-19 pandemic, an increased number of people working from home and students learning online have put an intense strain on data centers.

Businesses have suffered great losses from the Shelter-in-Place orders and restrictions placed on the way they operate. They can’t afford to lose more due to downtime in the data center.

Preventative Maintenance

The current pandemic has also caused many Data Center Managers to push their scheduled battery PM’s out several weeks or even months. This puts their UPS systems at greater risk of failure.

Keep in mind that batteries are chemical devices. Their state of health can change virtually overnight. Preventative maintenance and testing one day does not mean that they won’t fail the next day.

If I have a physical exam and bloodwork done today and am told that the results are good that doesn’t prevent me from coming down with an illness a few days later. The check up by my doctor didn’t prevent my illness anymore then a Preventative Maintenance can prevent battery failure hours or days later.

So, how do you protect this important life support?

Before we answer that, let’s first discuss what causes failures in the first place.

Battery Facts

There are four main factors that affect the health of your batteries. Keep in mind that batteries have a limited life, and will show a slow degradation of capacity until they reach around 80 percent of their initial rating.

These four factors affect battery life no matter the size of the UPS or where is it deployed.

  1. Ambient Temperature
    The rated capacity of a battery is based on an ambient temperature of 77 degrees (25 Celsius). Any variation to this temperature (up or down) can affect the battery’s performance and shorten its lifetime. For every 15 degrees F average temperature over 77F can reduce the battery life by 50 percent.
  2. Chemistry
    All batteries will require replacement after a certain period of time. They are electrochemical devices and their ability to deliver power and store energy decreases over time; regardless, of following manufacturer guidelines for proper storage, usage, and maintenance.
  3. Cycling
    The UPS operates on battery power during an outage. The battery is recharged for future use once the power is restored or it is switched to generator power. This is called a discharge cycle. The capacity of the battery is reduced slightly with every discharge and recharge cycle. The length of these discharge cycles determines the reduction in battery capacity. The battery can only undergo a certain number of discharge/recharge cycles before the chemistry is depleted. Once this happens, the cells fail and the battery must be replaced.
  4. Maintenance
    Batteries need to be maintained on a regular basis. Without maintenance and proper battery management, your UPS battery may experience heat-generating resistance at the terminals, improper loading, reduced protection and premature failure. Proper continuous battery management can extend the life of the battery string and identify bad batteries before they affect the other batteries.

Conditions of Battery Failure

Below are 7 conditions and the causes of data center battery failure:

  1. Sulfation of Plates
    Sitting discharged for an extended period, not on charge or being undercharged, such as battery shelf life being exceeded past manufacturer’s guidelines.
  2. Plate Separation
    Repeated cycling (charging and discharging), damage during handling and shipping, and overcharging.
  3. Grid corrosion
    Normal aging, operating in an acidic environment and high temperatures.
  4. Internal Short Circuit
    Heat (plates expand causing shorts), separator failure, handling and shipping, and grid corrosion
  5. External Short Circuit
    Human error (shortening terminals) and leaks
  6. Excessive gassing
    Often due to high temperatures or overcharging; electrolyte volume is decreased
  7. Drying Out
    Excessive gassing, high temperatures or overcharging, resulting in too little electrolyte for battery to function and provide full backup time

Source: Eaton Corporation – The Large Handbook of Batteries

In our next post, I’ll be addressing eleven ways to protect your data center batteries.

 

Primary Sidebar

Recent Posts

Cellwatch Battery Monitoring

Double Your Cellwatch Warranty with PTI 

remote telecom facilities

Remote, But Never Unmonitored

Roadmap to 0% Downtime

Categories

  • Battery Monitoring
  • Best Practices
  • Case Studies
  • Company Updates
  • Cooling Solutions
  • Events
  • Facility Monitoring
  • Industry Solutions
  • Power Monitoring
  • Power Solutions
  • Racks and Enclosures
  • Service Solutions
  • Tech Watch
  • Uncategorized

Footer

PTI Solutions: Predictive Technology, Inc.

11011 Q Suite 103C
Omaha, NE 68137

402.592.4259 877.592.4259

  • Line Card
  • Government Capability Statement
  • Products
  • Services
  • Industries
  • About
  • Blog
  • Contact
  • Facebook
  • LinkedIn

Site Footer

  • Email
  • Facebook
  • LinkedIn
  • YouTube

Copyright © 2025 Predictive Technology, Inc. · Privacy Policy · Terms and Conditions • Sitemap